Rack (1U)
RS700-E10-RS12U
RS700-E10-RS4U
RS300-E11-PS4
RS300-E11-RS4
RS700-E11-RS4U
RS700-E11-RS12U
Rack (2U)
RS720Q-E10-RS8U
RS720Q-E10-RS24
RS720Q-E10-RS24U
RS720-E10-RS12E
RS720-E10-RS24U
RS720-E10-RS24E
RS720-E10-RS12
RS720-E11-RS12U
RS720-E11-RS24U
RS720Q-E11-RS8U
RS720Q-E10-IM
Tower (5U)
TS100-E11-PI4
GPU Server & WS
ESC4000 G4
ESC4000 G4S
ESC4000 G4X
ESC8000 G4
E500 G5 SFF
E500 G5
ESC8000 G4/10G
ESC4000 DHD G4
Pro E500 G6
ESC4000-E10
ESC4000-E10S
ESC8000-E11
ESC8000-E11P
ExpertCenter E500 G9
Pro E500 G7
ESC4000-E11
ESC N8-E11

RS720Q-E9-RS8
¸ðµ¨
+È®´ë+
Processor / System Bus 2 x Socket P (LGA 3647) per Node
1st and 2nd Gen Xeon¢ç Scalable Processor Family
UPI (10.4 GT/s)
Generation E9
Core Logic Intel¢ç Lewisburg PCH C621
Memory Total Slots : 12 (6-channel per CPU, 6 DIMM per CPU) per Node
Capacity : Maximum up to 1536GB RDIMM
Memory Type :
DDR4 2933/2666/2400 /2133 RDIMM
DDR4 2933/2666/2400 /2133 LRDIMM
DDR4 2933/2666/2400 /2133 LR-DIMM 3DS
Memory Size :
128GB, 64GB, 32GB, 16GB, 8GB RDIMM/LRDIMM/LR-DIMM 3DS
Expansion Slots Per Node:
1 x PCI-E x16 (Gen3 x16 link), LP, HL
1 x OCP 2.0 Mezzanine (Gen3 x16 link)
Storage per Node
SATA Controller :
Marvell 88SE9230
HDD Bays 8 x 2.5" Hot-swap Storage Bays(All Support SATA/SAS/NVMe)

* each node could control 2 drives.
** CPU2 is necessary for the function of front hot-swap bays.
Networking per Node
1 x Dual Port Intel I350-AM2 Gigabit LAN controller + 1 x Mgmt LAN
Graphic Aspeed AST2500 with 64MB VRAM
Front I/O Ports N/A
Rear I/O Ports Per Node:
2 x USB 3.0 ports
1 x VGA port
2 x RJ-45 GbE LAN ports
1 x RJ-45 Management port
Switch/LED Switch/LED
OS Support Windows¢ç Server 2016
Windows¢ç Server 2012 R2
RedHat¢ç Enterprise Linux
SuSE¢ç Linux Enterprise Server
CentOS
Ubuntu
VMware
Citrix XenServer
Management Solution ASUS Control Center
ASMB9-iKVM for KVM-over-IP
Regulatory Compliance BSMI, CE, FCC(Class A)
Dimensions 800 x 444 x 88mm
Form Factor 2U
Weight Net Weight: 39 Kg
Gross Weight: 43 Kg
Power Supply 1+1 Redundant 1600(DPS-1600CB) 80 PLUS Platinum Power Supply or
1+0 Redundant 1600(DPS-1600CB) 80 PLUS Platinum Power Supply or
1+1 Redundant 2200W(DPS-2200AB-2 E) 80 PLUS Platinum Power Supply or
1+0 Redundant 2200W(DPS-2200AB-2 E) 80 PLUS Platinum Power Supply
Rating: 200-240 Vac, 9.5A/12.6A (for each inlet), 47-63Hz, Class I
Environment Operation temperature: 10¡É ~ 35¡É
Non operation temperature: -40¡É ~ 70¡É
Non operation humidity: 20% ~ 90% (Non condensing)
Note 1. If NVMe SSD is equipped, Intel¢ç VROC function could be enabled by VROC Hardware
Key.

2. For the full function of the system, please install both CPUs on each node.